Catalog | ABB industrial drives ACS880 single drives 19
EMC – electromagnetic compatibility
EMC according to EN 61800-3 (2004)
product standard
EN 61800-3
product
standard
EN 55011, product
family standard for
industrial, scientific
and medical (ISM)
equipment
EN 61000-6-4, generic
emission standard for
industrial environments
EN 61000-6-3, generic
emission standard for
residential, commercial and
light-industrial environment
1
st
environment, unrestricted distribution Category C1 Group 1, Class B Not applicable Applicable
1
st
environment, restricted distribution Category C2 Group 1, Class A Applicable Not applicable
2
nd
environment, unrestricted distribution Category C3 Group 2, Class A Not applicable Not applicable
2
nd
environment, restricted distribution Category C4 Not applicable Not applicable Not applicable
Type Voltage Frame sizes 1
st
environment,
restricted distribution,
C2, grounded network
(TN)
Option code
2
nd
environment, C3
grounded network (TN)
Option code
2
nd
environment, C3,
ungrounded network (IT)
Option code
ACS880-01 380 to 500 R1 to R9 +E202 +E200 +E210
(R6 to R9 frame size)
Each ACS880 model can be equipped with a built-in filter to
reduce high frequency emissions.
EMC standards
The EMC product standard (EN 61800-3 (2004)) covers the
specific EMC requirements stated for drives (tested with motor
and cable) within the EU. EMC standards such as EN55011,
or EN 61000-6-3/4, are applicable to industrial and domestic
equipment and systems including components inside the
drive. Drive units complying with the requirements of
EN 61800-3 are compliant with comparable categories in
EN 55011 and EN 61000-6-3/4, but not necessarily vice
versa. EN 55011 and EN 61000-6-3/4 do not specify cable
length or require a motor to be connected as a load. The
emission limits are comparable to EMC standards according
to the following table below.
1
st
environment versus 2
nd
environment
1
st
environment includes domestic premises. It also includes
establishments directly connected without an intermediate
transformer to a low-voltage power supply network that
supplies buildings used for domestic purposes.
2
nd
environment includes all establishments other than those
directly connected to a low voltage power supply network that
supplies buildings used for domestic purposes.
Selecting an EMC filter
The following table gives the correct filter selection.
EMC standards