Parameter listing and descriptions 237
ACH550-01 User's Manual
2907 USER MWh TRIG 0.0…6553.5 MWh
Sets the trigger point for the drive’s accumulated power consumption (in
megawatt hours) counter.
Value is compared to parameter 2908 value.
0.0 – Disables the trigger.
2908 USER MWh ACT 0.0…6553.5 MWh
Defines the actual value of the drive’s accumulated power consumption
(in megawatt hours) counter.
When parameter 2907 has been set to a non-zero value, the counter
starts.
When the actual value of the counter exceeds the value defined by
parameter 2907, a maintenance notice is displayed on the panel.
0.0 – Resets the parameter.
Code Description Range