244 Parameter listing and descriptions
ACH550-01 User's Manual
3023 WIRING FAULT 0=DISABLE, 1=ENABLE
Defines the drive response to cross wiring faults and to earth faults
detected when the drive is NOT running. When the drive is not running,
it monitors for:
• Improper connections of input power to the drive output (the drive can
display fault 35,
OUTP WIRING if improper connections are detected).
• Earth faults (the drive can display fault 16,
EARTH FAULT if an earth
fault is detected). Also, see parameter 3017
EARTH FAULT.
Note: Disabling wiring fault (earth fault) may void the warranty.
0 =
DISABLE – No response to either of the above monitoring results.
1 =
ENABLE – Displays a fault when this monitoring detects problems.
3024 CB TEMP FAULT 0=DISABLE, 1=ENABLE
Defines the drive response to control board overheating. Not for drives
with an OMIO control board.
0 =
DISABLE – No response
1 =
ENABLE – Displays a fault (37, CB OVERTEMP) and the drive coasts to
stop.