Pagina 1 - Module and ABB AC500 PLC

ACSM1Application GuideFieldbus Control with FPBA-01 PROFIBUS DP Adapter Module and ABB AC500 PLC

Pagina 2 - ACSM1 Drive Manuals

Introduction to the manual10Target audienceThis manual is intended for people who plan the drive application control, commission, use, and service the

Pagina 3

Starting up fieldbus communication and programming the ABB PLC (one-drive system)1003. From the Online menu, select Communication Parameters…. Check t

Pagina 4

Starting up fieldbus communication and programming the ABB PLC (one-drive system)1016. From the Online menu, click Login. The program asks you to down

Pagina 5 - Table of contents

Starting up fieldbus communication and programming the ABB PLC (one-drive system)102Test the program1. Start the drive by clicking the Off1_3 button a

Pagina 6

Starting up fieldbus communication and programming the ABB PLC (one-drive system)103 2. Test the other actions that you have made by clicking the acti

Pagina 7

Starting up fieldbus communication and programming the ABB PLC (one-drive system)104

Pagina 8

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)105Starting up fieldbus communication and programming the ABB PLC (m

Pagina 9

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)106CoDeSysConfigure communication with the SYCON fieldbus configurat

Pagina 10 - Related manuals

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)107SYCON.net4. -> The SYCON.net tool opens:5. From the Network me

Pagina 11 - Standards

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)1086. Drag and drop CM572-DPM on the green line. In the netConnect-D

Pagina 12 - Introduction to the manual

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)1098. In the netDevice field, right-click the CM572-DPM icon. Select

Pagina 13 - Fieldbus control description

Introduction to the manual11• ACSM1 Speed and Torque Control Program Firmware Manual (3AFE68848261 [English])• PROFIBUS DP Adapter Module FPBA-01 User

Pagina 14

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11010. In the Pages Three-View, click Device Assignment. Activate th

Pagina 15 - Drive control parameters

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11112. In the Pages Tree-view, click Station Table under Configurati

Pagina 16

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11213. Right-click the ABB Drives FPBA-01 icon connected to the purp

Pagina 17 - FBA communication profile

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11314. In the Configuration folder, click Parameters. Set the values

Pagina 18

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11415. In the netConnect field, click PPO-5, 4PKW + 10 PZD <Slot

Pagina 19 - Communication

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)11517. Check that the PLC is in the Stop state (Stop in the display)

Pagina 20

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)116Tool/StepProgramming the PLC main programProgramming of the PLC m

Pagina 21 - Cyclic data handling

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)117A list of the Global variables is shown below. Tool/StepProgram

Pagina 22 - Parameter setting examples

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)118The finished main program is shown below. Tool/StepProgramming t

Pagina 23

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)119 Tool/StepProgramming the PLC main program

Pagina 24

Introduction to the manual12

Pagina 25 - Control Word:

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)120 Tool/StepProgramming actionsProgramming of the actions is descri

Pagina 26

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)121The program shown below controls a two-axis toggle movement. For

Pagina 27 - / 100 = 10.00 m

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)122Add the action block toggle_movement to the main program. Tool/St

Pagina 28

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)123 Tool/StepProgramming visualizationsProgramming of the visualizat

Pagina 29

Starting up fieldbus communication and programming the ABB PLC (multi-axis system)124Tool/StepRunning and testing the programCoDeSysLoad and test the

Pagina 30

Example program for a two-axis loading machine125Example program for a two-axis loading machineWhat this chapter containsThis chapter presents an exam

Pagina 31 - Start-up flowchart

Example program for a two-axis loading machine126ProgramThe program for the toggle movement control is shown below.

Pagina 32

Example program for a two-axis loading machine127

Pagina 33

Example program for a two-axis loading machine128

Pagina 34 - Connections

Appendix A - How to find out the serial communication parameter values of your PC?129Appendix A - How to find out the serial communication parameter v

Pagina 35

Fieldbus control description13Fieldbus control descriptionWhat this chapter containsThe chapter describes how the drive can be controlled by external

Pagina 36

Appendix A - How to find out the serial communication parameter values of your PC?1302. Click the Hardware tab and then the Device Manager button.

Pagina 37

Appendix A - How to find out the serial communication parameter values of your PC?1314. The communication port settings are shown. Tool/StepHow to f

Pagina 38

Appendix A - How to find out the serial communication parameter values of your PC?132

Pagina 39

Further informationProduct and service inquiriesAddress any inquiries about the product to your local ABB representative, quoting the type designation

Pagina 40

3AUA0000049359 Rev C / ENEFFECTIVE: 2010-05-03ABB OyDrivesP.O. Box 184FI-00381 HELSINKIFINLANDTelephone +358 10 22 11Fax +358 10 22 22681www.abb.com

Pagina 41

Fieldbus control description14Setting up communication through a fieldbus adapter moduleBefore configuring the drive for fieldbus control, the adapter

Pagina 42

Fieldbus control description15After the module configuration parameters have been set, the drive control parameters (see section Drive control paramet

Pagina 43

Fieldbus control description16The fieldbus control interfaceThe cyclic communication between a fieldbus system and the drive consists of 16/32-bit inp

Pagina 44

Fieldbus control description17The Control Word and the Status WordThe Control Word (CW) is the principal means of controlling the drive from a fieldbu

Pagina 45

Fieldbus control description18When torque or speed reference scaling is selected (by parameter 50.04 FBA REF1 MODESEL / 50.05 FBA REF2 MODESEL), the f

Pagina 46

Fieldbus control description19State diagramThe following presents the state diagram for the FBA communication profile. For other profiles, see the Use

Pagina 47

ACSM1 Drive Manuals*A multilingual quick installation guide is included with the delivery.AC500 manuals can be found in the CoDeSys online help. Press

Pagina 48

Fieldbus control description20

Pagina 49

Starting up the FPBA-01 adapter for different communication profiles21Starting up the FPBA-01 adapter for different communication profilesOverviewThis

Pagina 50

Starting up the FPBA-01 adapter for different communication profiles22Parameter setting examplesThis section gives the recommended drive parameter set

Pagina 51

Starting up the FPBA-01 adapter for different communication profiles23PROFIdrive communication profile (Speed Control Mode) with PPO Type 1The start/s

Pagina 52

Starting up the FPBA-01 adapter for different communication profiles24ABB DRIVES communication profile (Speed/Torque Control Mode) with PPO Type 4The

Pagina 53

Starting up the FPBA-01 adapter for different communication profiles25*Read-only or automatically detected/set**ExampleThe start sequence for the para

Pagina 54

Starting up the FPBA-01 adapter for different communication profiles26PROFIdrive communication profile (Positioning Mode) with PPO Type 4The start/sto

Pagina 55

Starting up the FPBA-01 adapter for different communication profiles27*Read-only or automatically detected/setNote: By default, fieldbus is not the on

Pagina 56

Starting up the FPBA-01 adapter for different communication profiles28The velocity setpoint and actual values are scaled with the above example values

Pagina 57

Starting up fieldbus communication and programming the ABB PLC (one-drive system)29Starting up fieldbus communication and programming the ABB PLC (one

Pagina 58

Fieldbus Control with FPBA-01 PROFIBUS DPAdapter Module and ABB AC500 PLCApplication Guide3AUA0000049359 Rev CENEFFECTIVE: 2010-05-03© 2010 ABB Oy. Al

Pagina 59

Starting up fieldbus communication and programming the ABB PLC (one-drive system)30Equipment and programsEquipment used in the examples:• ACSM1-04 dem

Pagina 60

Starting up fieldbus communication and programming the ABB PLC (one-drive system)31Start-up flowchartThe steps of the start-up procedure are presented

Pagina 61

Starting up fieldbus communication and programming the ABB PLC (one-drive system)322 Set up the communication. In this section, you configure communic

Pagina 62

Starting up fieldbus communication and programming the ABB PLC (one-drive system)33– – – TWO - D R I V E S Y S T E M – – –Set up the communicat

Pagina 63

Starting up fieldbus communication and programming the ABB PLC (one-drive system)34ConnectionsACSM1-041 23 456789Installation of the TA510-CASE24 V DC

Pagina 64

Starting up fieldbus communication and programming the ABB PLC (one-drive system)35Installing the DriveStudio PC toolInsert the DriveStudio installati

Pagina 65

Starting up fieldbus communication and programming the ABB PLC (one-drive system)363. Click the Read me for installation button and read the instructi

Pagina 66

Starting up fieldbus communication and programming the ABB PLC (one-drive system)37Installing the PS551-MC Motion Control LibraryInsert the PS551-MC M

Pagina 67

Starting up fieldbus communication and programming the ABB PLC (one-drive system)38Installing additional GSD files and librariesThe GSD file DP-V0 for

Pagina 68

Starting up fieldbus communication and programming the ABB PLC (one-drive system)39If needed, copy additional GSD files to the following folder in you

Pagina 70

Starting up fieldbus communication and programming the ABB PLC (one-drive system)40StepSetting the drive control program parametersThis section lists

Pagina 71

Starting up fieldbus communication and programming the ABB PLC (one-drive system)41 StepSetting the drive control program parameters

Pagina 72

Starting up fieldbus communication and programming the ABB PLC (one-drive system)42 StepSetting the drive control program parameters

Pagina 73

Starting up fieldbus communication and programming the ABB PLC (one-drive system)43 StepSetting the drive control program parameters

Pagina 74

Starting up fieldbus communication and programming the ABB PLC (one-drive system)44StepSetting the drive control program parameters

Pagina 75

Starting up fieldbus communication and programming the ABB PLC (one-drive system)45Tool/StepSetting up the communicationFor setting up communication b

Pagina 76

Starting up fieldbus communication and programming the ABB PLC (one-drive system)464. In the New POU dialog box, select as shown below. 5. -> The

Pagina 77

Starting up fieldbus communication and programming the ABB PLC (one-drive system)476. In the Resources folder, double-click PLC Configuration. 7. In t

Pagina 78

Starting up fieldbus communication and programming the ABB PLC (one-drive system)488. Right-click the Couplers[FIX] folder. Select Append Subelement a

Pagina 79

Starting up fieldbus communication and programming the ABB PLC (one-drive system)499. In the Couplers[FIX] folder, right-click the Internal - none[SLO

Pagina 80

Table of contents5Table of contentsTable of contentsIntroduction to the manualApplicability . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 81

Starting up fieldbus communication and programming the ABB PLC (one-drive system)50CoDeSysConfigure communication with the SYCON fieldbus configurator

Pagina 82

Starting up fieldbus communication and programming the ABB PLC (one-drive system)51SYCON.net4. -> The SYCON.net tool opens:5. From the Network menu

Pagina 83

Starting up fieldbus communication and programming the ABB PLC (one-drive system)526. Drag and drop CM572-DPM on the green line. In the netConnect-Dri

Pagina 84

Starting up fieldbus communication and programming the ABB PLC (one-drive system)537. Drag and drop the FPBA-01 DP-V0 on the purple line. Tool/StepS

Pagina 85

Starting up fieldbus communication and programming the ABB PLC (one-drive system)548. In the netDevice field, right-click the CM572-DPM icon. Select C

Pagina 86

Starting up fieldbus communication and programming the ABB PLC (one-drive system)5510. In the Pages Three-View, click Device Assingnment. Activate the

Pagina 87

Starting up fieldbus communication and programming the ABB PLC (one-drive system)5612. In the Pages Tree-view, click Station Table under Configuration

Pagina 88

Starting up fieldbus communication and programming the ABB PLC (one-drive system)5713. Right-click the ABB Drives FPBA-01 icon connected to the purple

Pagina 89

Starting up fieldbus communication and programming the ABB PLC (one-drive system)5814. In the Configuration folder, click Parameters. Set the values o

Pagina 90

Starting up fieldbus communication and programming the ABB PLC (one-drive system)5915. In the netConnect field, click PPO-5, 4PKW + 10 PZD <Slot 1&

Pagina 91

Table of contents6Installing the PS551-MC Motion Control Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37Inst

Pagina 92

Starting up fieldbus communication and programming the ABB PLC (one-drive system)6016. Name the signals. In this example configuration, Input 1 is nam

Pagina 93

Starting up fieldbus communication and programming the ABB PLC (one-drive system)61 19. When the downloading is completed, right-click the CM572-DPM i

Pagina 94

Starting up fieldbus communication and programming the ABB PLC (one-drive system)62

Pagina 95

Starting up fieldbus communication and programming the ABB PLC (one-drive system)63Tool/StepProgramming the PLC main programIn this section, you progr

Pagina 96

Starting up fieldbus communication and programming the ABB PLC (one-drive system)643. Select the following libraries and click Open. Tool/StepProgram

Pagina 97

Starting up fieldbus communication and programming the ABB PLC (one-drive system)654. Double-click the PS551-MC folder and select the following librar

Pagina 98

Starting up fieldbus communication and programming the ABB PLC (one-drive system)665. In this example, the following libraries were inserted. Add func

Pagina 99

Starting up fieldbus communication and programming the ABB PLC (one-drive system)672. Replace the default text AND with text acsm1_access_dc. Now, the

Pagina 100 - Tool/Step

Starting up fieldbus communication and programming the ABB PLC (one-drive system)684. -> The Declare Variable assistant appears. In the Class dialo

Pagina 101

Starting up fieldbus communication and programming the ABB PLC (one-drive system)696. Configure input axis. Name it axis1 and press Enter. Class: VAR_

Pagina 102 - Test the program

Table of contents7Description of the program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 103

Starting up fieldbus communication and programming the ABB PLC (one-drive system)708. In this section a new program row is made before the access_axis

Pagina 104

Starting up fieldbus communication and programming the ABB PLC (one-drive system)71The program made so far is shown below. Right-click in the blank

Pagina 105 - What this chapter contains

Starting up fieldbus communication and programming the ABB PLC (one-drive system)72Add function block MC_ReadStatusThis function block returns in deta

Pagina 106

Starting up fieldbus communication and programming the ABB PLC (one-drive system)73Add function block MC_ResetThis function block makes the transition

Pagina 107

Starting up fieldbus communication and programming the ABB PLC (one-drive system)74The complete main program is shown hereThe complete program is show

Pagina 108

Starting up fieldbus communication and programming the ABB PLC (one-drive system)75View of the main program rows: Tool/StepProgramming the PLC ma

Pagina 109

Starting up fieldbus communication and programming the ABB PLC (one-drive system)76Tool/StepProgramming the PLC main program

Pagina 110

Starting up fieldbus communication and programming the ABB PLC (one-drive system)77Tool/StepProgramming actionsIn this section, you program actions an

Pagina 111

Starting up fieldbus communication and programming the ABB PLC (one-drive system)782. Name the action for example velocity. Select FBD for the program

Pagina 112

Starting up fieldbus communication and programming the ABB PLC (one-drive system)794. Create separate actions which are needed in the program for exam

Pagina 113

Table of contents8

Pagina 114

Starting up fieldbus communication and programming the ABB PLC (one-drive system)80Program velocity (MC_MoveVelocity)This Function Block commands a ne

Pagina 115

Starting up fieldbus communication and programming the ABB PLC (one-drive system)81The block in the previous picture runs axis1 constantly at velocity

Pagina 116

Starting up fieldbus communication and programming the ABB PLC (one-drive system)82Program positiong (MC_MoveAbsolute)This function block commands a c

Pagina 117

Starting up fieldbus communication and programming the ABB PLC (one-drive system)83Program relative movement (MC_MoveRelative)This function block comm

Pagina 118

Starting up fieldbus communication and programming the ABB PLC (one-drive system)84Program homing (MCA_Home)This function block commands the axis to p

Pagina 119

Starting up fieldbus communication and programming the ABB PLC (one-drive system)85Tool/StepProgramming actions

Pagina 120 - Programming actions

Starting up fieldbus communication and programming the ABB PLC (one-drive system)86Row 0001This section is the main switch. When the drive needs to be

Pagina 121

Starting up fieldbus communication and programming the ABB PLC (one-drive system)87Call the actions into the main programTo activate the actions that

Pagina 122

Starting up fieldbus communication and programming the ABB PLC (one-drive system)88The action boxes are shown at the end of the main program as follow

Pagina 123 - Programming visualizations

Starting up fieldbus communication and programming the ABB PLC (one-drive system)89Tool/StepProgramming visualizationsCoDeSysIn this section, you prog

Pagina 124

Introduction to the manual9Introduction to the manualWhat this chapter containsThis chapter describes the target audience, purpose and contents of thi

Pagina 125 - Description of the program

Starting up fieldbus communication and programming the ABB PLC (one-drive system)90Create an empty visualization fieldClick the Visualization tab. Rig

Pagina 126

Starting up fieldbus communication and programming the ABB PLC (one-drive system)91Create buttonsCreate buttons for the needed switches, for example,

Pagina 127

Starting up fieldbus communication and programming the ABB PLC (one-drive system)922. Configure the button as follows. Right-click the button. From th

Pagina 128

Starting up fieldbus communication and programming the ABB PLC (one-drive system)934. In the Category: dialog box, select Input. Under Input, tick Tog

Pagina 129

Starting up fieldbus communication and programming the ABB PLC (one-drive system)945. After making all buttons, the visualization field looks like thi

Pagina 130

Starting up fieldbus communication and programming the ABB PLC (one-drive system)95Create indicators1. In the upper tool bar, click the Bar display bu

Pagina 131

Starting up fieldbus communication and programming the ABB PLC (one-drive system)96Create visuaization elements1.Visualization elements are ready-made

Pagina 132

Starting up fieldbus communication and programming the ABB PLC (one-drive system)972. Double-click the created element. In the Visualization dialog bo

Pagina 133 - Further information

Starting up fieldbus communication and programming the ABB PLC (one-drive system)98 3. Add other elements in the same way as described above.Note: In

Pagina 134 - EFFECTIVE: 2010-05-03

Starting up fieldbus communication and programming the ABB PLC (one-drive system)99Tool/StepRunning and testing the programCoDeSysIn this section, you

Comentarios a estos manuales

Sin comentarios